function [H,Z,swro_Z,ro_water,ro_salt,Mw,Ms,Rw,T0,eta,sigma,p_r,rho_r,C_r,swro_L,swro_alpha,swro_R,swro_KK,swro_x_r,swro_b1,swro_b2,J_r,swro_gamma,swro_gamma2,swro_W_r,L,alpha,R,KK,x_r,b1,b2,Q_r,gamma,gamma2,W_r,cE,pE,rho_E,J_sf_0,J_wf_0,Pd_0,Pd_L,Pf_L,Q_sf_0,pd_0,pf_0,pd_L,pf_L,HP_eff,LP_eff,T_eff,V_m,ERD_eff,ERD_fric,A_ERD,eta_ERD,mix_density,pw,pe,swro_beta_fix,beta_fix,mixer_ERD,version,fig,swro_KF,swro_KD,KF,KD]= Sim_0b_data(input1, input2)
%% Sim_0b_data(input)
%
% Data for Simulation in chapter 3
%
% SWRO-PRO hybrid system I (realistic ERD)
%
% option_data = 0.1
%
% Input:
% input1 - x
% input2 - x
%% model versions
version=zeros(1,10);
% version(1)=0 if co-current, 1 otherwise
version(2)=1; % 0 = SWRO beta fixed
version(3)=0; % 0 = PRO beta fixed
version(4)=1; % 0 = ideal SWRO
version(5)=1; % 0 = ideal PRO
% ERD
version(6)=3;
% version(6) = 0 --> only SWRO (no ERD)
% version(6) = 1 --> only SWRO (with ERD)
% version(6) = 2 --> only PRO
% version(6) = 3 --> SWRO-PRO hybrid system (with one ERD)
% version(6) = 4 --> SWRO-PRO hybrid system (with two ERDs)
version(7)=1; % 1 = ICP and ECP for SWRO
version(8)=1; % 1 = ICP and ECP for PRO
%% Membrane unit properties
H = 1e-3; % height of the membrane [m]
ro_water = 1000; % mass density of water [kg/m^3]
ro_salt = 2165; % mass density of salt [kg/m^3]
Mw = 18; % molecular weight of water [kg/kmol]
Ms = 58.44; % molecular weight of salt [kg/kmol]
Rw = 462; % gas constant of water [J/(kg K)]
T0 = 297; % temperature [K]
eta = 1.3e-3; % seawater viscosity [kg/(m s)]
p_r = 1e5; % pressure [Pa]=[kg/ms^2]
rho_r = 1e3; % density [kg/m^3]
C_r = 1; % salt concentration [%]
%% SWRO
swro_Z=1; % width of SWRO membrane [m]
swro_L=4; % length of SWRO membrane [m]
if version(6)== 2; swro_L=1; end
swro_alpha = 5.0815e-9; % SWRO water permeablity co-efficient [s/m]
swro_R =0.96; % SWRO salt rejection rate
swro_KK = 1e-2; % SWRO ICP mass transfer coefficient
swro_KD = 1/swro_KK; % SWRO ECP draw side mass transfer coefficient
swro_KF = 1/swro_KK; % SWRO ECP fresh side mass transfer coefficient
swro_x_r=swro_L^2; % x_r=swro_L^2 since x = linspace(0,1,n) (if x = linspace(0,swro_L,n) then x_r=swro_L;)
swro_b1 = H/swro_x_r; % H/swro_L ratio
swro_b2 = swro_Z/swro_x_r; % Z/swro_L ratio
J_r = sqrt(H^3/swro_x_r*p_r*rho_r); % flux [kg/s^2]
swro_gamma= swro_x_r * p_r * swro_alpha /J_r; % SWRO scaling factor - mass balance
swro_gamma2= J_r^2./(swro_x_r^2 * p_r * rho_r); % SWRO scaling factor - momentum balance
swro_W_r=J_r*p_r/rho_r; % net work [W/m^2]
sigma=0.999 ; % Rejection coefficient
swro_beta_fix=4.43e-4/J_r*swro_x_r; % value for fixed SWRO beta [kg/sm^2]
%% PRO
Z=1; % width of the PRO membrane [m]
L=1.5; % length of the PRO membrane [m]
alpha = 5.47e-9; % water permeablity co-efficient [s/m]
R =0.94; % salt rejection rate [1]
KK=7.13e2; % mass transfer coefficient [sm^2/kg]
KD=1/KK; % PRO ECP draw side mass transfer coefficient [sm^2/kg]
KF=1/KK; % PRO ECP fresh side mass transfer coefficient [sm^2/kg]
x_r=L^2; % x_r=L^2 since x = linspace(0,1,n) (if x = linspace(0,L,n) then x_r=L;)
b1 = H/x_r; % H/L ratio
b2 = Z/x_r; % Z/L ratio
Q_r = sqrt(H^3/x_r*p_r*rho_r); % flux [kg/s^2]
gamma= x_r * p_r * alpha /Q_r ; % PRO scaling factor - mass balance
gamma2= Q_r^2./(x_r^2 * p_r * rho_r); % PRO scaling factor - momentum balance
W_r=Q_r*p_r/rho_r; % net work [W/m^2]
beta_fix =1.71e-4/Q_r*x_r; % value for fixed PRO beta [kg/sm^2]
%% Sea Water
cE= 35/983/C_r; % salt concentration in seawater
pE= 1e5/p_r; % external pressure
rho_E=(cE + 1)./(ro_water*cE/ro_salt + 1); % density of incomming seawater
%% SWRO operating conditions
J_sf_0 = 0; % salt flux in fresh side at 0
J_wf_0 = 0; % water flux in fresh side at L
Pf_L = pE; % pressure fresh side at L
Pd_0 = 66e5/p_r; % pressure draw side at 0
Pd_L = 60e5/p_r; % pressure draw side at L (not need in the hybrid system)
%% PRO operation conditions
Q_sf_0 = 0; % salt flux in fresh side at 0
pf_L = pE; % pressure of fresh side at L
pd_0 = 12e5/p_r; % pressure draw side at 0
pd_L = 14.6e5/p_r; % pressure of fresh side at 0
pf_0 = 1.3e5/p_r; % pressure draw side at L
%% ERD/Turbine/Pump parameters
T_eff = .95; % turbine efficiency
HP_eff = .9; % high pressure pump efficiency
LP_eff = .95; % low pressure pump efficiency
V_m=0.052; % Volumetric mixing
ERD_eff=.96; % ERD unit pressure efficiency
ERD_fric=5e-04; % ERD friction coefficient
A_ERD=H*swro_Z; % cross sectional area of ERD inflows/outflows
eta_ERD=0.01; % leak of high pressure brine
mix_density=997/rho_r; % density of mixture in ERD
pw=2; % water price [$/m^3]
pe=0.5; % electricity price [$/kWh]
mixer_ERD=1; % PRO Draw outlet mixer adjustment (only if 2nd ERDs) (mixer_ERD=1 --> all flow to ERD2 no turbine needed)
%% display figures
%fig=[1,0,0,0,0,0,0,0,1,0,0]; % f(i)=1 --> figure i will be displayed
fig=[0,0,0,0,0,0,0,0,0,0,0]; % f(i)=1 --> figure i will be displayed
%% model specific changes:
% co-current
if pd_0 > pd_L; version(1)=0; else; version(1)=1; end
% no SWRO needed (--> use trivial data)
if version(6) == 2; version(4)=0; Pd_0=40; Pd_L=35; end
end